Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Res ; 254: 121319, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38422692

RESUMO

To support the reactivation of urban rivers and estuaries for bathing while ensuring public safety, it is critical to have access to real-time information on microbial water quality and associated health risks. Predictive modelling can provide this information, though challenges concerning the optimal size of training data, model transferability, and communication of uncertainty still need attention. Further, urban estuaries undergo distinctive hydrological variations requiring tailored modelling approaches. This study assessed the use of Bayesian Networks (BNs) for the prediction of enterococci exceedances and extrapolation of health risks at planned bathing sites in an urban estuary in Sydney, Australia. The transferability of network structures between sites was assessed. Models were validated using a novel application of the k-fold walk-forward validation procedure and further tested using independent compliance and event-based sampling datasets. Learning curves indicated the model's sensitivity reached a minimum performance threshold of 0.8 once training data included ≥ 400 observations. It was demonstrated that Semi-Naïve BN structures can be transferred while maintaining stable predictive performance. In all sites, salinity and solar exposure had the greatest influence on Posterior Probability Distributions (PPDs), when combined with antecedent rainfall. The BNs provided a novel and transparent framework to quantify and visualise enterococci, stormwater impact, health risks, and associated uncertainty under varying environmental conditions. This study has advanced the application of BNs in predicting recreational water quality and providing decision support in urban estuarine settings, proposed for bathing, where uncertainty is high.


Assuntos
Monitoramento Ambiental , Qualidade da Água , Monitoramento Ambiental/métodos , Estuários , Saúde Pública , Teorema de Bayes , Enterococcus
2.
Sci Total Environ ; 780: 146462, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33774303

RESUMO

Risk-based approaches are used to define performance standards for water and wastewater treatment to meet health-based targets and to ensure safe and reliable water quality for desired end use. In this study, a screening level QMRA for a non-membrane based indirect potable reuse (IPR) system utilizing the sequential managed aquifer recharge technology (SMART) concept was conducted. Ambient removals of norovirus, Campylobacter and Cryptosporidium in advanced water treatment (AWT) steps were combined in a probabilistic QMRA utilizing Bayesian networks constructed in Netica. Results revealed that all pathogens complied with disease burden at the 95th percentile, and according to the assumptions taken about pathogen removal, Cryptosporidium was the pathogen with the greatest risk. Through systematic sensitivity analysis, targeted scenario analysis, and backwards inferencing, critical control points for each pathogen were determined, demonstrating the usefulness of Bayesian networks as a diagnostic tool in quantifying risk of water reuse treatment scenarios.


Assuntos
Criptosporidiose , Cryptosporidium , Água Potável , Purificação da Água , Animais , Teorema de Bayes , Medição de Risco , Águas Residuárias
3.
Water Res ; 124: 605-617, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28820991

RESUMO

Ozonation of wastewater has gained popularity because of its effectiveness in removing colour, UV absorbance, trace organic chemicals, and pathogens. Due to the rapid reaction of ozone with organic compounds, dissolved ozone is often not measurable and therefore, the common disinfection controlling parameter, concentration integrated over contact time (CT) cannot be obtained. In such cases, alternative parameters have been shown to be useful as surrogate measures for microbial removal including change in UV254 absorbance (ΔUVA), change in total fluorescence (ΔTF), or O3:TOC (or O3:DOC). Although these measures have shown promise, a number of caveats remain. These include uncertainties in the associations between these measurements and microbial inactivation. Furthermore, previous use of seeded microorganisms with higher disinfection sensitivity compared to autochthonous microorganisms could lead to overestimation of appropriate log credits. In our study, secondary treated wastewater from a full-scale plant was ozonated in a bench-scale reactor using five increasing ozone doses. During the experiments, removal of four indigenous microbial indicators representing viruses, bacteria and protozoa were monitored concurrent with ΔUVA, ΔTF, O3:DOC and PARAFAC derived components. Bayesian methods were used to fit linear regression models, and the uncertainty in the posterior predictive distributions and slopes provided a comparison between previously reported results and those reported here. Combined results indicated that all surrogate parameters were useful in predicting the removal of microorganisms, with a better fit to the models using ΔUVA, ΔTF in most cases. Average adjusted determination coefficients for fitted models were high (R2adjusted>0.47). With ΔUVA, one unit decrease in LRV corresponded with a UVA mean reduction of 15-20% for coliforms, 59% for C. perfringens spores, and 11% for somatic coliphages. With ΔTF, a one unit decrease in LRV corresponded with a TF mean reduction of 18-23% for coliforms, 71% for C. perfringens spores, and 14% for somatic coliphages. Compared to previous studies also analysed, our results suggest that microbial reductions were more conservative for autochthonous than for seeded microorganisms. The findings of our study suggested that site-specific analyses should be conducted to generate models with lower uncertainty and that indigenous microorganisms are useful for the measurement of system performance even when censored observations are obtained.


Assuntos
Desinfecção , Ozônio , Purificação da Água , Teorema de Bayes , Água
4.
Water Res ; 122: 269-279, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28609730

RESUMO

Ultrafiltration is an effective barrier to waterborne pathogens including viruses. Challenge testing is commonly used to test the inherent reliability of such systems. Performance validation seeks to demonstrate the adequate reliability of the treatment system. Appropriate and rigorous data analysis is an essential aspect of validation testing. In this study we used Bayesian analysis to assess the performance of a full-scale ultrafiltration system which was validated and revalidated after five years of operation. A hierarchical Bayesian model was used to analyse a number of similar ultrafiltration membrane skids working in parallel during the two validation periods. This approach enhanced our ability to obtain accurate estimations of performance variability, especially when the sample size of some system skids was limited. This methodology enabled the quantitative estimation of uncertainty in the performance parameters and generation of predictive distributions incorporating those uncertainties. The results indicated that there was a decrease in the mean skid performance after five years of operation of approximately 1 log reduction value (LRV). Interestingly, variability in the LRV also reduced, with standard deviations from the revalidation data being decreased by a mean 0.37 LRV compared with the original validation data. The model was also useful in comparing the operating performance of the various parallel skids within the same year. Evidence of differences was obtained in 2015 for one of the membrane skids. A hierarchical Bayesian analysis of validation data provides robust estimations of performance and the incorporation of probabilistic analysis which is increasingly important for comprehensive quantitative risk assessment purposes.


Assuntos
Ultrafiltração , Vírus , Purificação da Água , Teorema de Bayes , Humanos , Reprodutibilidade dos Testes
5.
Water Res ; 109: 144-154, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27883919

RESUMO

Chlorine disinfection of biologically treated wastewater is practiced in many locations prior to environmental discharge or beneficial reuse. The effectiveness of chlorine disinfection processes may be influenced by several factors, such as pH, temperature, ionic strength, organic carbon concentration, and suspended solids. We investigated the use of Bayesian multilayer perceptron (BMLP) models as efficient and practical tools for compiling and analysing free chlorine and monochloramine virus disinfection performance as a multivariate problem. Corresponding to their relative susceptibility, Adenovirus 2 was used to assess disinfection by monochloramine and Coxsackievirus B5 was used for free chlorine. A BMLP model was constructed to relate key disinfection conditions (CT, pH, turbidity) to observed Log Reduction Values (LRVs) for these viruses at constant temperature. The models proved to be valuable for incorporating uncertainty in the chlor(am)ination performance estimation and interpolating between operating conditions. Various types of queries could be performed with this model including the identification of target CT for a particular combination of LRV, pH and turbidity. Similarly, it was possible to derive achievable LRVs for combinations of CT, pH and turbidity. These queries yielded probability density functions for the target variable reflecting the uncertainty in the model parameters and variability of the input variables. The disinfection efficacy was greatly impacted by pH and to a lesser extent by turbidity for both types of disinfections. Non-linear relationships were observed between pH and target CT, and turbidity and target CT, with compound effects on target CT also evidenced. This work demonstrated that the use of BMLP models had considerable ability to improve the resolution and understanding of the multivariate relationships between operational parameters and disinfection outcomes for wastewater treatment.


Assuntos
Desinfecção , Águas Residuárias , Teorema de Bayes , Cloro , Desinfetantes , Humanos , Vírus
6.
Water Res ; 85: 304-15, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26342914

RESUMO

Risk management for wastewater treatment and reuse have led to growing interest in understanding and optimising pathogen reduction during biological treatment processes. However, modelling pathogen reduction is often limited by poor characterization of the relationships between variables and incomplete knowledge of removal mechanisms. The aim of this paper was to assess the applicability of Bayesian belief network models to represent associations between pathogen reduction, and operating conditions and monitoring parameters and predict AS performance. Naïve Bayes and semi-naïve Bayes networks were constructed from an activated sludge dataset including operating and monitoring parameters, and removal efficiencies for two pathogens (native Giardia lamblia and seeded Cryptosporidium parvum) and five native microbial indicators (F-RNA bacteriophage, Clostridium perfringens, Escherichia coli, coliforms and enterococci). First we defined the Bayesian network structures for the two pathogen log10 reduction values (LRVs) class nodes discretized into two states (< and ≥ 1 LRV) using two different learning algorithms. Eight metrics, such as Prediction Accuracy (PA) and Area Under the receiver operating Curve (AUC), provided a comparison of model prediction performance, certainty and goodness of fit. This comparison was used to select the optimum models. The optimum Tree Augmented naïve models predicted removal efficiency with high AUC when all system parameters were used simultaneously (AUCs for C. parvum and G. lamblia LRVs of 0.95 and 0.87 respectively). However, metrics for individual system parameters showed only the C. parvum model was reliable. By contrast individual parameters for G. lamblia LRV prediction typically obtained low AUC scores (AUC < 0.81). Useful predictors for C. parvum LRV included solids retention time, turbidity and total coliform LRV. The methodology developed appears applicable for predicting pathogen removal efficiency in water treatment systems generally.


Assuntos
Cryptosporidium parvum/fisiologia , Giardia lamblia/fisiologia , Modelos Teóricos , Esgotos/parasitologia , Eliminação de Resíduos Líquidos/métodos , Teorema de Bayes , Purificação da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...